The complete assembly acts as a single sensor to monitor the average temperature in a duct.
Duct averaging temperature sensor.
Duct temperature sensors.
No settings or field calibration required.
Averaging duct temperature sensors are used to sense temperature in discharge duct.
Averaging duct temperature sensors are used to sense temperature in discharge duct.
Duct averaging temperature sensors are designed specifically for hvac system temperature control.
Te 701bx vav discharge air temp sensor.
Enclosure mounting styles come in plastic or metal for both nema 1 and nema 4 applications and are all plenum rated.
Automated logic s duct averaging temperature sensors feature closed cell foam to seal the probe insertion hole and absorb vibration.
Where failure or malfunction of the sensor could lead to personal injury or property damage to the controlled equipment or other property additional precautions must be designed into the control system.
A duct averaging sensor is a common way to measure the true temperature of all the stratified air.
Duct averaging temperature sensor should be mounted across a duct in a serpentine fashion with bends in a smooth ark using clip.
Te 205 ex te 205 eu te 205 a m p space temperature sensors te 205 f te 706 b.
Mounting tabs allow for easy installation directly to the wall of the duct.
Minco 1000 ohm platinum rtd rangeable temperature transmitter rigid averaging thermistor sensor and more building automation productions available to ship.
Te 703 704 pipe temperature sensors.
Overview averaging sensor mounting methods averaging probes are available as flexible or rigid.
Te 707 flexible averaging temp sensor.
The averaging sensor is for duct mounting and temperature measurement of stratified air across the duct to give the average temperature along the length of the sensor.
Duct average temperature sensor installation instructions duct average temperature sensor the averaging sensor incorporates several sensors encapsulated at equal distances across the length of the probe.
The flexible probe is made of aluminum and made in different lengths for a custom duct fit.
Platinum positive temperature coefficient sensor.
The averaging sensors come in thermistor compatible with most bas systems available today averaging sensors come with a foambacked handy box and in12ft 3 5m 24ft 7m 39ft 12m lengths.
The te 6300m series duct averaging temperature sensor is intended to provide an input to equipment under normal operating conditions.
Use to troubleshoot system operation.
C7130 the c7130a b wall mount air temperature sensors provide the input required by the r7380j l w7100 w7600 w7620 and excel 500 control systems to sense air temperature in indoor spaces.
Outdoor air temperature sensors.