It also protects the chimney from the corrosion that can be inflicted by the acidic flue gases that emanate from the fire.
Do i need a flue liner in my chimney for a gas fire.
Today it is not a necessity to install a gas fire or stove into a traditional chimney setting with a conventional flue.
Also you should get a new chimney liner when you decide to convert your fireplace.
A chimney liner protects the chimney liners masonry and joints from the heat of the fire.
Homeowners with gas or electric inserts most likely do not need a new liner because those types of fuel don t produce enough heat to damage a masonry chimney.
My house is 17 years old and i want a multi fuel stove on checking my chimney i found there is a pot liner do i still need a flexi flu liner as well.
By preventing overheating and corrosion a chimney liner ensures a longer life for your chimney.
Larger is not necessarily better when it comes to your flue liner.
Installing lining would reduce any risk of gas fire not working.
Now apparently the flue lining can only be installed by an hetas technician despite being just a pipe and being quoted 1000 this would be added to the gas fire installation 900 on top of the gas box itself 2000.
Whether you go from gas to wood burning or vice versa it s important that you install a new chimney liner because different materials are more suited for different fireplace types.
Only use a gas safe registered fitter.
It was a lot cheaper than british gas so got it done.
Many gas fired appliances offer you the option of a balanced flue system which will exit discreetly from your property via a twin wall pipe.
Cracked masonry should be addressed from an energy savings perspective a lot of air could be escaping from your home depending on where the damage to the chimney is located but it s not likely to be a fire hazard.
Probably not most everything can be installed with a round liner with the exception of some liners for fireplaces.
I recently did a powerflush with a tradesman who quoted 250 for a powerflush and i got it done.
If the chimney is in a good state with no leakages visible when smoke tested including checking in the loft area and all bedrooms and providing your new fires manufacturers instructions state it s ok to fit without a liner.
Chimney systems that predate 1965 will often require a modern lining solution for the following reasons.
New chimneys may require relining to suit the fuel type being used a gas flue liner may not be suitable for other fuels.
You should be ok.