48 travis 2016 clearance to the side of any non mechanical supply air inlet.
Direct vent gas fireplace clearance to windows.
The fire clearances for a gas heater that s what we re discussing right that s direct vented can vary depending on the flue vent connector or vent material and type from 0 to perhaps 6 tell me the brand and model of your heater and we ll take a look too.
Clearance distance from gas vent termination cap to any mechanical air supply inlet.
1 16 of 235 results for direct vent gas fireplace empire comfort systems tahoe clean face direct vent mv deluxe 42 lp fireplace with blower.
How a direct vent gas fireplace works.
The heat can be shifted above the unit or to another room.
Only 3 left in stock order soon.
Typical clearance from an operable window to a direct vented gas appliance vent outlet.
6 inches 15 cm for appliances up to 10 000 btu hr 3 kw 12 inches 30 cm for appliances between 10 000 btu hr 3 kw and 100 000 btu hr 30 kw 36 inches 91 cm for appliances above 100 000 btu hr 30 kw 3.
And is available with enviro linear models only.
These fireplaces burn efficiently enough to be a heat source but not too efficient to where the fire lacks realism.
We marked on your gas vent photo the two measurements that are typically made.
4 4 out of 5 stars 2.
As per b149 1 a vent shall not terminate within 12 of a door or window for appliances with inputs from 10 000 100 000 btuh so yes you are correct at 12 quick navigation fireplaces top site areas.
The small pipe vents exhaust gases to the outdoors while the outer larger pipe pulls in oxygen for combustion.
Gas direct vent fireplaces a gas direct vent fireplace is the most popular choice by both builders and homeowners for new construction or a remodel.
The enviro heat distribution kit does not change the mantel requirements.
Available with their linear direct vent zero clearance fireplaces the enviro heat distribution kit also makes it possible to hang a tv above a fireplace.
Empire tahoe deluxe 36 direct vent ng millivolt fireplace.
The vertical distance to the window and the horizontal distance to the window from the nearest point of the gas vent.
The outer pipe also acts as an insulator to keep the surface temperature of the vent system lower.
This article series gives typical clearance distance requirements between the termination cap of a gas fireplace or fireplace insert and other building or site features such as windows doors other mechanical system components air intakes exhausts.
Direct vent fireplaces use a coaxial vent system which features a small pipe within a larger pipe.